By Wang S.K.

Show description

Read or Download Air-conditioning and refrigeration PDF

Similar ventilation & air conditioning books

Evaporative Air-Conditioning: Applications for Environmentally Friendly Cooling (World Bank Technical Papers)

'Under the perfect stipulations and purposes, evaporative air-conditioning (EAC) applied sciences delivers first-class cooling and air flow with minimum strength intake. 'Evaporative air-conditioning applied sciences are getting used more and more in residential and advertisement purposes world wide. EAC applied sciences, which depend upon water as a coolant instead of on chemical refrigerants, are low cost to supply and use and feature vital environmental advantages.

Statik der Seilkonstruktionen: Theorie und Zahlenbeispiele (German Edition)

Dieses Buch behandelt die theoretischen Grundlagen der statischen examine von Seilkonstruktionen. Es werden sowohl einzelne Seile als auch ebene und raumli che Seilsysteme betrachtet. Das erste Kapitel vermittelt eine allgemeine Charakteristik und eine Uber sicht uber die Eigenschaften der Seilkonstruktionen.

Rock and Pop Venues: Acoustic and Architectural Design

Renowned song performs a considerable position in such a lot people’s existence. The call for and fiscal profit of Rock and dad concert events is big and nonetheless expanding with the diminished profit on recorded song. in line with the 1st ever medical investigations on recommendable acoustics for amplified song performed via the writer, this publication units ahead particular directions for acoustical engineers to optimize the acoustics in present or destiny halls for amplified track.

Extra resources for Air-conditioning and refrigeration

Example text

The amount of outdoor air required for metabolic oxidation is rather small. 3 cfm/ft2 15 25 These requirements are based on the analysis of dilution of CO2 as the representative human bioeffluent to an allowable indoor concentration of 1000 ppm. Field measurements of daily maximum CO2 levels in office buildings reported by Persily (1993) show that most of them were within the range 400 to 820 ppm. 055 Exposure 24 24 1 8 hr hr hr hr 1 year 3 months Here exposure means average period of exposure.

Equip with a terminal that mixes the supply air with the space air or air from the ceiling plenum. During the cool-down period, due to the high dew point temperature of the plenum air when the air system is started, the supply air temperature must be controlled to prevent condensation. 1 The worship hall of a church uses a package system with a basic air system. The summer space sensible cooling load is 75,000 Btu/hr with a latent load of 15,000 Btu/hr. Other design data for summer are as follows: Outdoor summer design temperature: dry bulb 95°F and wet bulb 75°F Summer indoor temperature: 75°F with a space relative humidity of 50%: Temperature rise: fan power 2°F supply duct 2°F Relative humidity of air leaving cooling coil: 93% Outdoor air requirement: 1800 cfm Determine the 1.

For convenience in analysis, sound frequencies are often subdivided into eight octave bands. An octave is a frequency band in which the frequency of the upper limit of the octave is double the frequency of the lower limit. An octave band is represented by its center frequency, such as 63, 125, 250, 500, 1000, 2000, 4000, and 8000 Hz. On 1000 Hz the octave band has a higher limit of 1400 Hz and a lower limit of 710 Hz. Human ears do not respond in the same way to low frequencies as to high frequencies.

Download PDF sample